PMC Thermocouple
ISO9001:2000

 

    
   

     
PRODUCT CODE: TE/TE

Our customers have grown to expect only the highest quality product from PMC A Division of R-SCC. We are continually committed to meet the specific needs of industry and our customers. This construction includes the single conductors insulated with FEP (Fluorinated Ethylene Propylene), laid parallel and jacketed also with FEP. FEP was commercially introduced in 1960 by Dupont and is a true thermoplastic. It is applied as an insulation or jacket by conventional extruder processes. It retains useful strength and flexibility over broad ranges of environmental temperature or thermal aging; and a volume resistivity above 1018 OHM/Sq., both are at the top of measurable range. The dielectric constant is 2.1 from 102 to 107 Hz, above which drops slightly with increasing frequency (less than 3% change at 1010 Hz). The dissipation factor show no change with temperature and only slight change with frequency-between 60 Hz and 10,000 Hz, the factor ranges from 0.0002 to 0.0007, obtaining a maximum value at 1 Mhz.

The thermocouple grade products shown are used to form temperature sensors and the extension grade products become the interconnecting link in the temperature system.

Suggested operating temperature is -90°F to 400°F (-67°C to 204°C). The insulation on the individual conductors and the jacketing are both color coded to ANSI standards for quick identification of conductors and calibration.

You will find our qualified sales and engineering staff eager to assist in selecting a design to meet the requirements of your specific application.

Wire
Grade
Gauge
Size
Wire
Type
Part Numbers
Type J Type K Type T
THERMOCOUPLE
20 Solid J-TE/TE-20 K-TE/TE-20 T-TE/TE-20
THERMOCOUPLE
20 7/8 Stranded J-TE/TE-20F K-TE/TE-20F T-TE/TE-20F
THERMOCOUPLE
24 Solid J-TE/TE-24 K-TE/TE-24 T-TE/TE-24
THERMOCOUPLE
24 7/32 Stranded J-TE/TE-24F K-TE/TE-24F T-TE/TE-24F
THERMOCOUPLE
30 Solid J-TE/TE-30 K-TE/TE-30 T-TE/TE-30
EXTENSION
16 Solid JX-TE/TE-16 KX-TE/TE-16 TX-TE/TE-16
EXTENSION
20 Solid JX-TE/TE-20 KX-TE/TE-20 TX-TE/TE-20
EXTENSION
20 7/28 Stranded JX-TE/TE-20F KX-TE/TE-20F TX-TE/TE-20F
EXTENSION
24 Solid JX-TE/TE-24 KX-TE/TE-24 TX-TE/TE-24
EXTENSION
24 7/32 Stranded JX-TE/TE-24F KX-TE/TE-24F TX-TE/TE-24F

Wire
Grade
Gauge
Size
Wire
Type
Part Numbers
Type E Type N Type RS
THERMOCOUPLE
20 Solid E-TE/TE-20 N-TE/TE-20  
THERMOCOUPLE
20 7/8 Stranded E-TE/TE-20F N-TE/TE-20F  
THERMOCOUPLE
24 Solid E-TE/TE-24 N-TE/TE-24  
THERMOCOUPLE
24 7/32 Stranded E-TE/TE-24F N-TE/TE-24F  
THERMOCOUPLE
30 Solid E-TE/TE-30 N-TE/TE-30  
EXTENSION
16 Solid EX-TE/TE-16 NX-TE/TE-16 RSX-TE/TE-16
EXTENSION
20 Solid EX-TE/TE-20 NX-TE/TE-20 RSX-TE/TE-20
EXTENSION
20 7/28 Stranded EX-TE/TE-20F NX-TE/TE-20F RSX-TE/TE-20F
EXTENSION
24 Solid EX-TE/TE-24 NX-TE/TE-24 RSX-TE/TE-24
EXTENSION
24 7/32 Stranded EX-TE/TE-24F NX-TE/TE-24F RSX-TE/TE-24F


Color Code & Initial Calibration Tolerances for Thermocouple Wire:
 Thermocouple Type
 Color Code  Initial Calibration Tolerances
 Wire Alloys ANSI
Symbol
+/-
Individual
Jacket  Temperature Range Standard
Limits
Special
Limits
 *Iron(+) vs.
Constantan™(-)
J White/Red Brown +32°F (0°C) to +545°F (+285°C)
+545°F (285°C) to +1400°F (+750°C)
± 4°F (2.2°C)
± .75%
± 2°F (1.1°C)
± .4%
 CHROMEL™(+) vs.
ALUMEL™(-)
K Yellow/Red Brown -330°F -200°C) to -165°F (-110°C)
-165 °F (-110°C) to +32°F (0°C)
+32°F (0°C) to +545°F (+285°C)
+545°F (285°C) to +2300°F (+1250°C)
± 2%
± 4°F (2.2°C)
± 4°F (2.2°C)
± .75%
± 2°F (1.1°C)
± .4%
 Copper(+) vs.
Constantan™(-)
T Blue/Red Brown -330°F (-200°C) to -85°F (-65°C)
-85°F (-65°C) to +270°F (+130°C)
+270°F (130°C) to +660°F (+350°C)
± 1.5%
± 1.8°F (1°C)
± .75%
± .8%
± .9°F (.5°C)
± .4%
 CHROMEL™(+) vs.
Constantan(-)
E Purple/Red Brown -330°F -20(0°C) to -270°F (-170°C)
-270°F (-170°C) to +480°F (+250°C)
+480°F (+250°C) to +640°F (+340°C)
+640°F (+340°C) to +1600°F (+900°C)
± 1%
± 3°F (1.7°C)
± 3°F (1.7°C)
± .5%
± 1.8°F (1°C)
± 1.8°F (1°C)
± .4%
± .4%
 Nicrosil(+) vs.
Nisil(-)
N Orange/Red Brown +32°F (0°C) to +545°F (+285°C)
+545°F (285°C) to +2300°F (+1250°C)
± 4°F (2.2°C)
± .75%
± 2°F (1.1°C)
± .4%

Color Code & Initial Calibration Tolerances for Extension Wire
 Thermocouple Type
 Color Code  Initial Calibration Tolerances
 Wire Alloys ANSI
Symbol
+/-
Individual
Jacket  Temperature Range Standard
Limits
Special
Limits
 *Iron vs. Constantan
JX White/Red Black +32°F (0°C) to +400°F (+200°C)
± 4°F (2.2°C) ± 2°F (1.1°C)
 CHROMEL® vs. ALUMEL®
KX Yellow/Red Yellow +32°F (0°C) to +400°F (+200°C) ± 4°F (2.2°C) ± 2°F (1.1°C)
 Copper vs. Constantan
TX Blue/Red Blue -75°F (-60°C) to +210°F (+100°C) ± 2 °F (1.1°C) ± 1°F (.5°C)
 CHROMEL® vs. Constantan
EX Purple/Red Purple +32°F (0°C) to +400°F (+200°C) ± 3°F (1.7°C) ± 2°F (1.1°C)
 Nicrosil vs. Nisil
NX Orange/Red Orange +32°F (0°C) to +400°F (+200°C) ± 4°F (2.2°C) ± 2°F (1.1°C)
 Copper vs. Copper Alloy
SX
RX
Black/Red Green +75°F (25°C) to +400°F (+200°C) ±9°F (5°C)  

NOTE: Percent limits apply directly to temperature in °C units, but for °F equivalents are applied to the numbers of °F above or below the ice point (+32°F).
(i.e. Limit (°F) = (Temp. °F-32°F) x Percentage)
Thermocouple wire cannot be expected to meet the limits of error at temperatures below the ice point unless specified at time of purchase.
* Magnetic
CHROMEL®and ALUMEL®are registered trademarks of Hoskins Manufacturing Company.
   
TE/TE Physical Properties
Gauge Nominal
Insulation
Wall (in.)
Nominal
Jacket
Wall (in.)
Nominal
Diameter
(in.)
Approx.
Ship. Wt
(lbs) per M
 Characteristics Insulation Jacket
 Specific Gravity
2.2 2.2
16 7/24
16
20 7/8
24F
24
30
.008
.008
.008
.008
 
.010
.010
.010
.010
 
.090 x .160
.087 x .154
.074 x .128
.068 x .116
 
24
23
12
11
 
 Durometer Hardness
55 55
 Tensile Strength; psi (min)
3000 3000
 Elongation; %(min)
200 200
 Minimum Bend Radius
3 x O.D. 5 x O.D.
 Abrasion Resistance
Very Good Very Good
 Cut Through Resistance
Good Good
 Moisture Resistance
Excellent Excellent
 Solder Iron Resistance
Good Good
 Service Temperature
400°F(200°C) continuous 482°F (250°C) single exposure 400°F(200°C) continuous 482°F (250°C) single exposure
 Flame Test
Self-extinguishing Self-extinguishing

 
Pricing Policy: Shipments will be invoiced at PMC's prices in effect at time of shipment. Quotations are given with an escalation clause and prices, terms, and conditions are subject to change without prior notice. PMC will however, make every attempt to hold to current quoted prices. All prices are in United States currency, and shall be subject to correction for errors, unless otherwise stated in writing to PMC.
Reels, Spools & Coils: All shipments, unless specified otherwise by PMC, are make on non-returnable reels, spools or coils in one continuous length.

Shortages &
Returns:
All claims for shortage or incorrect material must be made within 10 days after receipt of the goods to which such claim pertains. Goods may only be returned for credit within 1 month of the date of authorization. Goods that are special in any way shall not be returned to PMC. Material returned for any reason, without written authorization will be refused a n returned at shipper's expense. A return request must be processed through our Manchester, N.H. sales office.
Tolerances:

Due to allowances in manufacturing processes for wire, cable and similar products, PMC-A Division of R-SCC reserves the right to ship variation of ± 10% from the quantity of such goods ordered. Physical tolerances shown are nominal. Shipping weights are an average of all types of conductors and are listed for estimation only. These weights can vary substantially due to different types of spools, reels and/or conductors.

The material contained in the document is presented in good faith and believed to be reliable and accurate. However, because testing conditions may vary and material quality or information that may be provided in whole or part by others may be beyond our control, no warranty, expressed or implied, is given PMC-A Division of R-SCC can assume no liability for results obtained or damages incurred through the application of the data tests presented.
Note: PMC-A Division of R-SCC reserves the right to substitute an equal product on all registered trademark items.

 

Build your own Part Number