PMC Thermocouple
ISO9001:2000

 

    
   

     
PRODUCT CODE: TEAB and TAAB

Our customers have grown to expect only the highest quality product from PMC A Division of R-SCC. We are continuously committed to meet the specific needs of industry and our customers.

The AutoBond™ construction was designed to eliminate the 'leakage path through wire' often found in autoclave applications when traditional wire constructions are employed. This construction is available with either 400°F (204°C) FEP insulation or 500°F (260°C) PFA Telflon insulation.

The color-coded, insulated singles are bonded together in a proprietary process, eliminating the need for a conventional jacket. With no outer jacket to strip back, the conductors are easily separated (yet firmly attached), retain their small size/weight configuration, and will not kink and knot in handling. The exceptional characteristics of FEP and PFA, with a low coefficient of friction, and excellent resistance to moisture and chemicals further enhance the AutoBond construction capabilities.

Other applications include aerospace flight test and environmental test chambers where AutoBond's small size and weight are critical. The AutoBond construction with special calibration accuracy's over narrow spans are available for medical applications.

You will find our qualified sales and engineering staff eager to assist in selecting a design to meet the requirements of your specific applications.

Wire
Grade
Gauge
Size
Wire
Type
FEP Part Numbers
Type J Type K Type T
THERMOCOUPLE
24 Solid J-TEAB-24 K-TEAB-24 T-TEAB-24
THERMOCOUPLE
30 Solid J-TEAB-30   K-TTEAB-30 T-TEAB-30

Wire
Grade
Gauge
Size
Wire
Type
PFA Part Numbers
Type J Type K Type T
THERMOCOUPLE
24 Solid J-TAAB-24 K-TAAB-24 T-TAAB-24
THERMOCOUPLE
30 Solid J-TAAB-30 K-TAAB-30 T-TAAB-30


Color Code & Initial Calibration Tolerances for Thermocouple Wire:
 Thermocouple Type  Color Code  Initial Calibration Tolerances
 Wire Alloys ANSI
Symbol
+/-
Individual
 Temperature Range Standard
Limits
Special
Limits
 *Iron(+) vs. Constantan(-)
J White/Red +32°F (0°C) to +545°F (+285°C)
+545°F (285°C) to +1400°F (+750°C)
± 4°F (2.2°C)
± .75%
± 2°F (1.1°C)
± .4%
 Chromel®(+ ) vs. Alumel®(-)
K Yellow/Red -330°F -200°C) to -165°F (-110°C)
-165 °F (-110°C) to +32°F (0°C)
+32°F (0°C) to +545°F (+285°C)
+545°F (285°C) to +2300°F (+1250°C)
± 2%
± 4°F (2.2°C)
± 4°F (2.2°C)
± .75%
± 2°F (1.1°C)
± .4%
 Copper(+) vs. Constantan(-)
T Blue/Red -330°F (-200°C) to -85°F (-65°C)
-85°F (-65°C) to +270°F (+130°C)
+270°F (130°C) to +660°F (+350°C)
± 1.5%
± 1.8°F (1°C)
± .75%
± .8%
± .9°F (.5°C)
± .4%
 Chromel®(+) vs. Constantan(-)
E Purple/Red -330°F -20(0°C) to -270°F (-170°C)
-270°F (-170°C) to +480°F (+250°C)
+480°F (+250°C) to +640°F (+340°C)
+640°F (+340°C) to +1600°F (+900°C)
± 1%
± 3°F (1.7°C)
± 3°F (1.7°C)
± .5%
± 1.8°F (1°C)
± 1.8°F (1°C)
± .4%
± .4%
 Nicrosil(+) vs. Nisil(-)
N Orange/Red +32°F (0°C) to +545°F (+285°C)
+545°F (285°C) to +2300°F (+1250°C)
± 4°F (2.2°C)
± .75%
± 2°F (1.1°C)
± .4%

NOTE: Percent limits apply directly to temperature in °C units, but for °F equivalents are applied to the numbers of °F above or below the ice point (+32°F).
(i.e. Limit (°F) = (Temp. °F-32°F) x Percentage)
Thermocouple wire cannot be expected to meet the limits of error at temperatures below the ice point unless specified at time of purchase.
* Magnetic
CHROMEL® and ALUMEL®are registered trademarks of Hoskins Manufacturing Company.
   
TEAB/TAAB Physical Properties Gauge Nominal
Insulation
Wall (in.)
Nominal
Diameter
(in.)
Approx.
Ship. Wt
(lbs) per M
 Characteristics FEP Autobond PFA Autobond
 Specific Gravity 2.15 2.15
 
24
30
 
 
 
.008
.006
 
 
 
.036 x .072
.022 x .044
 
 
 
4
2
 
 
 Durometer Hardness 55 55
 Tensile Strength; psi (min) 3000 3000
 Elongation; %(min) 200 300
 Minimum Bend Radius 10 x O.D. 10 x O.D.
 Abrasion Resistance Very Good Very Good
 Cut Through Resistance Good Good
 Moisture Resistance Excellent Excellent
 Solder Iron Resistance Good Good
 Service Temperature 400°F(200°C) continuous 482°F (250°C) single exposure 400°F(200°C) continuous 482°F (250°C) single exposure
 Flame Test Non-flammable Non-flammable

 
Pricing Policy: Shipments will be invoiced at PMC's prices in effect at time of shipment. Quotations are given with an escalation clause and prices, terms, and conditions are subject to change without prior notice. PMC will however, make every attempt to hold to current quoted prices. All prices are in United States currency, and shall be subject to correction for errors, unless otherwise stated in writing to PMC.
Reels, Spools & Coils: All shipments, unless specified otherwise by PMC, are make on non-returnable reels, spools or coils in one continuous length.
Shortages & Returns: All claims for shortage or incorrect material must be made within 10 days after receipt of the goods to which such claim pertains. Goods may only be returned for credit within 1 month of the date of authorization. Goods that are special in any way shall not be returned to PMC. Material returned for any reason, without written authorization will be refused a n returned at shipper's expense. A return request must be processed through our Manchester, N.H. sales office.
Tolerances:

Due to allowances in manufacturing processes for wire, cable and similar products, PMC-A Division of R-SCC reserves the right to ship variation of ± 10% from the quantity of such goods ordered. Physical tolerances shown are nominal. Shipping weights are an average of all types of conductors and are listed for estimation only. These weights can vary substantially due to different types of spools, reels and/or conductors.

The material contained in the document is presented in good faith and believed to be reliable and accurate. However, because testing conditions may vary and material quality or information that may be provided in whole or part by others may be beyond our control, no warranty, expressed or implied, is given PMC-A Division of R-SCC can assume no liability for results obtained or damages incurred through the application of the data tests presented.
Note: PMC-A Division of R-SCC reserves the right to substitute an equal product on all registered trademark items.

 

Build your own Part Number