PRODUCT
CODE: FB/FB
Our customers have grown to expect only the highest quality
products from PMC A Division of R-SCC.
This construction
is one of the earliest insulations used and is perhaps still most widely
used. It consists of single conductors insulated with a fiberglass braid
then impregnated with a special binder to improve moisture and abrasion
resistance. The singles are then laid parallel and a braided jacket
of the same material is applied and impregnated.
While wire gauge
size, calibration and atmosphere will affect maximum useful temperature
in applications, this insulation is designated to withstand a maximum
continuous use at 900°F (482°C) and a single exposure use at
1000°F (537°C). (Note: Impregnations retained to 400°F (204°C).
Wire
Grade |
Gauge
Size |
Wire
Type |
Part
Numbers |
| Type
J |
Type
K |
Type
T |
Type
E |
Type
N |
Type
R/S |
|
THERMOCOUPLE
|
16 |
Solid |
J-FB/FB-16 |
K-SF/FBK-20 |
T-FB/FB-20 |
E-FB/FB-20 |
N-FB/FB-20 |
|
|
THERMOCOUPLE
|
20 |
Solid |
J-FB/FB-20 |
K-FB/FB-20 |
T-FB/FB-20 |
E-FB/FB-20 |
N-FB/FB-20 |
|
|
THERMOCOUPLE
|
20
7/28 |
Stranded |
J-FB/FB-20F |
K-FB/FB-20F |
T-FB/FB-20F |
E-FB/FB-20F |
N-FB/FB-20F |
|
|
THERMOCOUPLE
|
24 |
Solid |
J-FB/FB-24 |
K-FB/FB-24 |
T-FB/FB-24 |
E-FB/FB-24 |
N-FB/FB-24 |
|
|
EXTENSION
|
16 |
Solid |
JX-FB/FB-16 |
KX-SF/FB-16 |
TX-SF/FB-16 |
EX-SF/FB-16 |
NX-SF/FB-16 |
RSX-FB/FB-16 |
|
EXTENSION
|
20 |
Solid |
JX-FB/FB-20 |
KX-FB/FB-20 |
TX-FB/FB-20 |
EX-FB/FB-20 |
NX-FB/FB-20 |
RSX-FB/FB-20 |
|
Color
Code & Initial Calibration Tolerances for Thermocouple Wire:
|
Thermocouple
Type
|
Color
Code |
Initial
Calibration Tolerances |
| Wire
Alloys |
ANSI
Symbol |
+/-
Individual |
Jacket |
Temperature
Range |
Standard
Limits |
Special
Limits |
|
*Iron(+)
vs. Constantan(-)
|
J |
White/Red |
Brown
w/Black Tracer |
+32°F
(0°C) to +545°F (+285°C)
+545°F (285°C) to +1400°F (+750°C)
|
±
4°F (2.2°C)
± .75% |
±
2°F (1.1°C)
± .4% |
|
Chromel®(+)
vs. Alumel®(-)
|
K |
Yellow/Red |
Brown
w/Yellow Tracer |
-330°F
-200°C) to -165°F (-110°C)
-165 °F (-110°C) to +32°F (0°C)
+32°F (0°C) to +545°F (+285°C)
+545°F (285°C) to +2300°F (+1250°C)
|
±
2%
± 4°F (2.2°C)
± 4°F (2.2°C)
± .75% |
±
2°F (1.1°C)
± .4% |
|
Copper(+)
vs.
Constantan(-)
|
T |
Blue/Red |
Brown
w/Blue Tracer |
-330°F
(-200°C) to -85°F (-65°C)
-85°F (-65°C) to +270°F (+130°C)
+270°F (130°C) to +660°F (+350°C)
|
±
1.5%
± 1.8°F (1°C)
± .75% |
±
.8%
± .9°F (.5°C)
± .4% |
|
Chromel®(+) vs. Constantan(-)
|
E |
Purple/Red |
Brown
w/Purple |
-330°F
-20(0°C) to -270°F (-170°C)
-270°F (-170°C) to +480°F (+250°C)
+480°F (+250°C) to +640°F (+340°C)
+640°F (+340°C) to +1600°F (+900°C)
|
±
1%
± 3°F (1.7°C)
± 3°F (1.7°C)
± .5% |
±
1.8°F (1°C)
± 1.8°F (1°C)
± .4%
± .4% |
|
Nicrosil(+) vs. Nisil(-)
|
N |
Orange/Red |
Brown
w/Orange Tracer |
+32°F
(0°C) to +545°F (+285°C)
+545°F (285°C) to +2300°F (+1250°C)
|
±
4°F (2.2°C)
± .75% |
±
2°F (1.1°C)
± .4% |
|
Color
Code & Initial Calibration Tolerances for Extension Wire:
|
Thermocouple
Type
|
Color
Code |
Initial
Calibration Tolerances |
| Wire
Alloys |
ANSI
Symbol |
+/-
Individual |
Jacket |
Temperature
Range |
Standard
Limits |
Special
Limits |
|
*Iron
vs. Constantan
|
JX |
White/Red |
Black |
+32°F
(0°C) to +400°F (+200°C)
|
±
4°F (2.2°C) |
±
2°F (1.1°C) |
|
Chromel®vs. Alumel®
|
KX |
Yellow/Red |
Yellow |
+32°F
(0°C) to +400°F (+200°C)
|
±
4°F (2.2°C) |
±
2°F (1.1°C) |
|
Copper
vs. Constantan
|
TX |
Blue/Red |
Blue |
-75°F
(-60°C) to +210°F (+100°C)
|
±
2°F (1.1°C) |
±
1°F (.5°C) |
|
Chromel® vs. Constantan
|
EX |
Purple/Red |
Purple |
+32°F
(0°C) to +400°F (+200°C) |
±
3°F (1.7°C) |
±
2°F (1.1°C) |
|
Nicrosil vs. Nisil
|
NX |
Orange/Red |
Orange |
+32°F
(0°C) to +400°F (+200°C) |
±
4°F (2.2°C) |
±
2°F (1.1°C) |
|
Copper
vs. Copper Alloy
|
SX
RX |
Black/Red |
Green |
+75°F
(25°C) to +400°F (+200°C)
|
±
9°F (5°C) |
|
|
| NOTE: |
Percent
limits apply directly to temperature in °C units, but for °F equivalents
are applied to the numbers of °F above or below the ice point (+32°F).
(i.e. Limit (°F) = (Temp. °F-32°F) x Percentage) |
 |
Thermocouple
wire cannot be expected to meet the limits of error at temperatures
below the ice point unless specified at time of purchase. |
* |
Magnetic |
 |
CHROMEL®and ALUMEL®are registered trademarks of Hoskins Manufacturing Company. |
|
FB/FB
Physical Properties
|
Gauge |
Nominal
Insulation
Wall (in.) |
Nominal
Jacket
Wall (in.) |
Nominal
Diameter
(in.) |
Approx.
Ship. Wt
(lbs) per M |
| Characteristics |
Insulation |
Jacket |
| Specific
Gravity |
2.54 |
2.54 |
|
|
|
| .080
x .144 |
| .060
x .106 |
| .066
x .118 |
| .048
x .082 |
| |
|
|
| Tensile
Strength; psi (min) |
250,000
at 1000°F (537°C) |
250,000
at 1000°F (537°C) |
| Elongation;
%(min) |
4.8 |
4.8 |
| Minimum
Bend Radius |
5
x O.D. |
10
x O.D. |
| Abrasion
Resistance |
Good |
Good |
| Cut
Through Resistance |
Very
Good |
Excellent |
| Moisture
Resistance |
Good |
Good |
| Solder
Iron Resistance |
Excellent |
Excellent |
| Service
Temperature |
500°F(260°C)
continuous 600°F (343°C) single exposure |
500°F(260°C)
continuous 1000°F (537°C) single exposure |
| Flame
Test |
Non-flammable |
Non-flammable |
|
|