PMC Thermocouple
ISO9001:2000

 

    
   

     
PRODUCT CODE: RB/RB

Our customers have grown to expect only the highest quality products from PMC A Division of R-SCC. Filaflex® was developed to operate in applications to withstand continuous temperatures as high as 1400°F (760°C) without flexing or abrasion. Filaflex is being used in applications to replace asbestos, or where standard fiberglass won’t stand up.

Filaflex designs contain single conductors insulated with a high tensile strength low alkali magnesia alumina silicate vitreous fiber braid. Prior to impregnation the insulation is inorganic, incombustible and will neither expand nor contract with moisture changes. Once the material has been braided onto the wire, it is impregnated with a special binder to improve moisture and abrasion resistance. The singles are then laid parallel and a braided jacket of the same material is
applied and impregnated.

Many customers use this product as singles twisted together with no jacket for expandable thermocouple applications. See Data sheet #146 for information. You will find our qualified sales and engineering staff eager to assist in selecting a design to meet the requirements of your specific application. Variations of this construction are available upon request, including protective metal coverings for improved abrasion resistance.




Grade of
Wire
Gauge
Size
Wire
Type
Part Numbers
Type J Type K Type E Type N
THERMOCOUPLE
14 Solid J-RB/RB-14 K-RB/RB-14 E-RB/RB-14 N-RB/RB-14
THERMOCOUPLE
16  Solid J-RB/RB-16 K-RB/RB-16 E-RB/RB-16 N-RB/RB-16
THERMOCOUPLE
20 Solid J-RB/RB-20 K-RB/RB-20 E-RB/RB-20 N-RB/RB-20

NOTE: The part numbers above represent the more popular constructions. However, other designs are available upon request.

Color Code & Initial Calibration Tolerances for Extension Wire:
 Thermocouple Type
 Color Code  Initial Calibration Tolerances
 Wire Alloys ANSI
Symbol
+/-
Individual
Jacket  Temperature Range Standard
Limits
Special
Limits
 *Iron(+) vs.
Constantan(-)
J White/Red White w/Black Tracer +32°F (0°C)  to +545°F (+285°C)
+545°F(+258°C)   to + 1400°F(+750°C)
± 4°F (2.2°C)
± .75%
± 2°F (1.1°C)
± .4%
 CHROMEL®(+) vs.
ALUMEL®(-)
K Yellow/Red White w/Yellow Tracer -330°F(-200°C)  to -165°F(-110°)
-165°F-110°C)  to +32°F(+0°C)
+32°F(+0°C)  to +545°F(+285°C)
+545°F(+285°C)  to+2300°F(+1250°C)

± 2°
± 4°F (2.2°C)
± 4°F (2.2°C)
±.75%


± 2°F (1.1°C)
± .4%
 Copper(+) vs.
Constantan(-)
T Blue/Red White w/Blue Tracer -330°F(-200°C)  to -85°F(-65°C)
-85°F(-65°C)  to +270°F(-+130°C)
+270°F(+130°C)  to +660°F(+350°C)
±1.5%
±1.8°F(1°C)
± .75%
± .8%
±.9°F(.5°C)
± 4°F
CHROMEL®(+) vs.
Constantan(-)
E Purple/Red White w/ Purple Tracer -330°F(-200°C)  to -270°F(-170°)
-270°F-170°C)  to +480°F(+250°C)
+480°F(+250°C)  to +640°F(+340°C)
+640°F(+340°C)  to+1600°F(+900°C)
± 1°
± 3°F (1.7°C)
± 3°F (1.7°C)
±.5°
±1.8°F(1°C)
±1.8°F(1°C)
± 4°F
± 4°F
 Nicrosil(+) vs. Nisil(-)
N Orange/Red White w/Orange Tracer +32°F (0°C)  to +545°F (+285°C)
+545°F(+285°C)  to+2300°F(+1250°C)
± 4°F (2.2°C)
± .75%
± 2°F (1.1°C)
± 4°F

NOTE: Percent limits apply directly to temperature in °C units, but for °F equivalents are applied to the numbers of °F above or below the ice point (+32°F).
(i.e. Limit (°F) = (Temp. °F-32°F) x Percentage)
Thermocouple wire cannot be expected to meet the limits of error at temperatures below the ice point unless specified at time of purchase.
* Magnetic
CHROMEL® and ALUMEL® are registered trademarks of Hoskins Manufacturing Company.
   
 Characteristics Insulation Jacket Gauge Nominal
Insulation
Wall (in.)
Nominal
Jacket
Wall (in.)
Nominal
Diameter
(in.)
Approx.
Ship. Wt
(lbs) per M
 Specific Gravity
2.48 2.48

14








16

.20

.012








.012

 

.012








.012

 

.112 x .200







.100 x .174

 

39








28

 

 Tensile Strength; psi (min)
500,000 p.s.i. 500,000 p.s.i.
 Elongation; %(min)
4.8% 4.8%
 Minimum Bend Radius
5 x O.D. 10 x O.D.
 Abrasion Resistance
Good Good
 Cut Through Resistance
Excellent Excellent
 Moisture Resistance
Good Good
 Solder Iron Resistance
Excellent Excellent
 Service Temperature
1400°F (760°C) continuous 1600°F (871°C) Single Exposure 1400°F (760°C) continuous 1600°F (871°C) Single Exposure
 Flame Test
Non-Flammable Non-Flammable

Pricing Policy:

Shipments will be invoiced at PMC's prices in effect at time of shipment. Quotations are given with an escalation clause and prices, terms, and conditions are subject to change without prior notice. PMC will however, make every attempt to hold to current quoted prices. All prices are in United States currency, and shall be subject to correction for errors, unless otherwise stated in writing to PMC.

Reels, Spools & Coils: All shipments, unless specified otherwise by PMC, are make on non-returnable reels, spools or coils in one continuous length.

Shortages & Returns:
All claims for shortage or incorrect material must be made within 10 days after receipt of the goods to which such claim pertains. Goods may only be returned for credit within 1 month of the date of authorization. Goods that are special in any way shall not be returned to PMC. Material returned for any reason, without written authorization will be refused a n returned at shipper's expense. A return request must be processed through our Manchester, N.H. sales office.
Tolerances:

Due to allowances in manufacturing processes for wire, cable and similar products, PMC-A Division of R-SCC reserves the right to ship variation of ± 10% from the quantity of such goods ordered. Physical tolerances shown are nominal. Shipping weights are an average of all types of conductors and are listed for estimation only. These weights can vary substantially due to different types of spools, reels and/or conductors.

The material contained in the document is presented in good faith and believed to be reliable and accurate. However, because testing conditions may vary and material quality or information that may be provided in whole or part by others may be beyond our control, no warranty, expressed or implied, is given PMC-A Division of R-SCC can assume no liability for results obtained or damages incurred through the application of the data tests presented.
Note: PMC-A Division of R-SCC reserves the right to substitute an equal product on all registered trademark items.