PMC Thermocouple
ISO9001:2000

 

    
   

     
PRODUCT CODE: TE/TE 041
  
Single conductors are carefully selected and matched to meet or exceed ANSI MC 96.1-1982 tolerances.

  
Each conductor is insulated with 8 mils nominal of -400°F to +400°F (-240°C to +204°C) flame resistant and low smoke FEP to insure insulation integrity.
  
Matched pairs are twisted to reduce the amount of electromagnetic interference.
    
The twisted pairs are cabled and a polyester backed aluminum shield with a tinned copper drain is helically applied overall to further reduce electrostatic noise. The shield overlaps approximately 25% to assure continual coverage during flexing.
  
This construction includes an insulated communication wire to transmit telephone or other signals during installation or service.
  
A rugged -400°F to +400°F(-240°C to +204°C) flame resistant and low smoke FEP Teflon jacket is applied over the pairs for excellent resistance to most corrosive substances, lubricants and weathering. This construction simplifies installation in cable trays and conduit due to its proprieties of low friction, good flexibility and mechanical strength.
  
When multi-pair constructions are purchased, the individual pairs are numbered for easy hookup.
  
The entire construction is color coded according to ANSI MC 96.1-1982 to aid in quick identification of both polarity and calibration.

  
A nylon ripcord is included for easy jacket stripping.
          
No. of Pairs Part Numbers
Type J Type K Type T Type E Type N Type R/S
1 JX-201TE/TE031-20U KX-201TE/TE31-20U TX-201TE/TE31-20U EX-201TE/TE31-20U NX-201TE/TE31-20U RSX-201TE/TE31-20U
4 JX-204TE/TE041-20U KX-204TE/TE041-20U TX-204TE/TE041-20U EX-204TE/TE041-20U NX-204TE/TE041-20U RSX-204TE/TE041-20U
6 JX-206TE/TE041-20U KX-206TE/TE041-20U TX-206TE/TE041-20U EX-206TE/TE041-20U NX-206TE/TE041-20U RSX-206TE/TE041-20U
8 JX-208TE/TE041-20U KX-208TE/TE041-20U TX-208TE/TE041-20U EX-208TE/TE041-20U NX-208TE/TE041-20U RSX-208TE/TE041-20U
12 JX-212TE/TE041-20U KX-212TE/TE041-20U TX-212TE/TE041-20U EX-212TE/TE041-20U NX-212TE/TE041-20U RSX-212TE/TE041-20U
16 JX-216TE/TE041-20U KX-216TE/TE041-20U TX-216TE/TE041-20U EX-216TE/TE041-20U NX-216TE/TE041-20U RSX-216TE/TE041-20U
20 JX-220TE/TE041-20U KX-220TE/TE041-20U TX-220TE/TE041-20U EX-220TE/TE041-20U NX-220TE/TE041-20U RSX-220TE/TE041-20U
24 JX-224TE/TE041-20U KX-224TE/TE041-20U TX-224TE/TE041-20U EX-224TE/TE041-20U NX-224TE/TE041-20U RSX-224TE/TE041-20U
36 JX-236TE/TE041-20U KX-236TE/TE041-20U TX-236TE/TE041-20U EX-236TE/TE041-20U NX-236TE/TE041-20U RSX-236TE/TE041-20U
50 JX-250TE/TE041-20U KX-250TE/TE041-20U TX-250TE/TE041-20U EX-250TE/TE041-20U NX-250TE/TE041-20U RSX-250TE/TE041-20U

NOTE: The part numbers above represent the more popular constructions. However, other designs are available upon request.

Color Code & Initial Calibration Tolerances for Extension Wire:
 Thermocouple Type  Color Code  Initial Calibration Tolerances
 Wire Alloys ANSI
Symbol
+/-
Individual
Jacket  Temperature Range Standard
Limits
Special
Limits
 *Iron vs. Constantan JX White/Red Black +32°F (0°C) to +400°F (+200°C) ± 4°F (2.2°C) ± 2°F (1.1°C)
 CHROMEL® vs. ALUMEL® KX Yellow/Red Yellow +32°F (0°C) to +400°F (+200°C) ± 4°F (2.2°C) ± 2°F (1.1°C)
 Copper vs. Constantan TX Blue/Red Blue -75°F (-60°C) to +210°F (+100°C) ± 2°F (1.1°C) ± 1°F (.5°C)
 CHROMEL® vs. Constantan EX Purple/Red Purple +32°F (0°C) to +400°F (+200°C) ± 3°F (1.7°C) ± 2°F (1.1°C)
 Nicrosil vs. Nisil NX Orange/Red Orange +32°F (0°C) to +400°F (+200°C) ± 4°F (2.2°C) ± 2°F (1.1°C)
 Copper vs. Copper Alloy SX / RX Black/Red Green +75°F (+25°C) to +400°F (+200°C) ± 9°F (5°C)    

NOTE: Percent limits apply directly to temperature in °C units, but for °F equivalents are applied to the numbers of °F above or below the ice point (+32°F).
(i.e. Limit (°F) = (Temp. °F-32°F) x Percentage)
Thermocouple wire cannot be expected to meet the limits of error at temperatures below the ice point unless specified at time of purchase.
* Magnetic
CHROMELŪ and ALUMELŪ are registered trademarks of Hoskins Manufacturing Company.
   
  
 TE/TE 041 Physical Properties: No. of Parts Nominal
Jacket
Thickness (mls)
Nominal
O.D.
(in.)
Min. Bend
Radius
(in.)
Maximum
Pulling
Tension
(lbs)
Average of
TC Types Net
WT/1000
Ft. (lbs.)
 Characteristics Insulation Jacket
 Operating Temperature (max.) 400°F (204°C) 400°F (204°C)
1
4
6
8
12
16
20
24
36
50
15
15
15
15
20
20
20
20
20
20
.131
.237
.275
.304
.371
.419
.439
.501
.573
.663
1.000
1.700
1.900
2.100
2.500
2.900
3.000
3.500
4.000
4.800
20
74
106
139
204
270
335
401
597
826
16
49
67
85
126
162
196
232
335
462
 Melting Point 530°F (277C) 530°F (277°C)
 Tensile Strength; psi (min) 2500 2500
 Elongation; %(min) 250 250
 Cold Bend
(Operating Temperature)
-4°F (-2°C) -4°F (-2°C)
 Specific Gravity 2.15 2.15
 Water Absorgtion 0.1% 0.1%
 Heat Aged 7 Days at Indicated  Temp.
 -Redication of Tensile Strength
 -Retention of Elongation
 
 
85%
85%
 
 
85%
85%
 Flammability Self Extinguishing Self Extinguishing
   
Pricing Policy:

Shipments will be invoiced at PMC's prices in effect at time of shipment. Quotations are given with an escalation clause and prices, terms, and conditions are subject to change without prior notice. PMC will however, make every attempt to hold to current quoted prices. All prices are in United States currency, and shall be subject to correction for errors, unless otherwise stated in writing to PMC.

Reels, Spools & Coils: All shipments, unless specified otherwise by PMC, are make on non-returnable reels, spools or coils in one continuous length.

Shortages & Returns:
All claims for shortage or incorrect material must be made within 10 days after receipt of the goods to which such claim pertains. Goods may only be returned for credit within 1 month of the date of authorization. Goods that are special in any way shall not be returned to PMC. Material returned for any reason, without written authorization will be refused a n returned at shipper's expense. A return request must be processed through our Manchester, N.H. sales office.
Tolerances:

Due to allowances in manufacturing processes for wire, cable and similar products, PMC-A Division of R-SCC reserves the right to ship variation of ± 10% from the quantity of such goods ordered. Physical tolerances shown are nominal. Shipping weights are an average of all types of conductors and are listed for estimation only. These weights can vary substantially due to different types of spools, reels and/or conductors.

The material contained in the document is presented in good faith and believed to be reliable and accurate. However, because testing conditions may vary and material quality or information that may be provided in whole or part by others may be beyond our control, no warranty, expressed or implied, is given PMC-A Division of R-SCC can assume no liability for results obtained or damages incurred through the application of the data tests presented.
Note: PMC-A Division of R-SCC reserves the right to substitute an equal product on all registered trademark items.